Global Parameter Settings |
|
SET MODE PARAMETER |
Function |
Available Values |
Notes |
|
ANL |
Automatic Noise Limiter |
OFF/ON |
Reduces noise in AM mode |
|
AFC |
Automatic Frequency Control |
OFF/ON |
Helps to correct for slightly off frequency transmissions |
|
ATT |
Attenuator |
OFF/ON |
-30dB cut to help deal with excessively strong signals |
|
RF GAIN |
Radio frequency Gain |
11 steps |
Variable IF gain |
|
VOLUME |
Audio volume level |
39 levels |
|
|
KEY-TOUCH BEEP |
Enables Beeps |
OFF/ON |
Keypad confirmation bleeps |
|
BEEP LEVEL |
Acknowledgement
Beep Level |
39 levels |
Chimes when setting - nice touch! |
|
BACKLIGHT |
Backlight illumination mode |
ON/OFF/AUTO |
Defines the operation of the display backlighting |
|
POWER SAVE |
Power Save |
OFF/AUTO |
Extends battery duration |
|
NOISE BLANKER |
Noise Blanker
|
OFF/ON |
Reduces Pulse noise in SSB & CW modes |
|
AF FILTER |
Audio frequency filter |
OFF/ON |
Provides low cut to suppress subtones |
|
AM ANTENNA |
Selects external or bar antenna |
EXT / BAR |
|
|
FM ANTENNA |
Selects external or headphone lead |
EXT / EARPHONE |
Works in FM broadcast band only |
|
LOCK |
Selects severity level of control locks |
NORMAL / NO SQL / NO VOL / ALL |
|
|
DIAL SPEED-UP |
Dial Speed Up |
OFF/ON |
|
|
MONITOR |
Selects action of monitor button |
PUSH / HOLD |
Latching or non-latching |
|
AUTO POWER OFF |
Selects duration of APO |
30-120min |
Also BUSY and OFF settings |
|
SCAN PAUSE |
Sets duration of scan pause |
2,4,6,8,10,12,14,16,18,20 SEC, HOLD |
|
|
SCAN RESUME |
Sets duration after which scanning resumes |
0,1,2,3,4,5SEC, HOLD |
|
|
SCAN STOP BEEP |
Beep on scan stop |
OFF/ON |
|
|
SCOPE AF OUTPUT |
|
OFF/ON |
|
|
LCD CONTRAST |
Display contrast |
16 steps |
|
|
CI-V ADDRESS |
CI-V Address |
|
|
|
CI-V BAUD RATE |
CI-V Baud Rate |
|
|
|
CI-V TRANSCEIVE |
CI-V Transceiver enable |
|
|